===== NL7559KW7/Abs.Vocht-informatie [Testend => alleen ter info & evaluatie!!!] ===== Datum = 17-04-2024 Tijd = 06:39:00 Locatie => Rel.Vocht & Temperatuur => Abs.Vocht AV, Dampdruk (=P) & Dauwpunt (=Td) Buiten-sensors, tuin +2,5m (1*) => 83.0 % 13.1 °C => AV= 9.5 g/m^3 @ P= 12.5 hPa & Td= 10.6 °C +1,5m (3*) => 84.7 % 10.1 °C => AV= 8.1 g/m^3 @ P= 10.5 hPa & Td= 7.9 °C +0,1m (1*) => 86.0 % 13.3 °C => AV= 9.9 g/m^3 @ P= 13.1 hPa & Td= 11.3 °C Referentie-sensors, binnen/ begane grond +0,05m(2*) => 54.5 % 16.2 °C => AV= 7.5 g/m^3 @ P= 10.0 hPa & Td= 7.4 °C Kruipruimte-sensors -0,5m (1*) => 100.0 % 15.0 °C => AV= 12.8 g/m^3 @ P= 17.0 hPa & Td= 15.3 °C -0,8m (2*) => 100.0 % 15.0 °C => AV= 12.8 g/m^3 @ P= 17.0 hPa & Td= 15.3 °C -1,1m (1*) => 61.0 % 13.2 °C => AV= 7.0 g/m^3 @ P= 9.2 hPa & Td= 0 °C => R.V. Piekwaarde : RV_Buiten = 91.0 % => A.V. Gemiddeld : AV_Buiten = 9.0 g/m^3 & AV_Kruipruimte = 13.0 g/m^3 => Delta_AV = -4.0 g/m^3 => Tdauw Gemiddeld : Td_Buiten = 10.0 °C & Td_Kruipruimte = 15.0 °C => Delta_Tdauw = -5.0 °C [ Gewenst voor ventilatie: RV_Buiten < 75% @ T > 12°C, met Delta_AV << 0 en Delta_Tdauw << 0 ] => Ventilatie-advies = NIET ventileren Foute HP3001-sensoren krijgen vervangingswaarden (als indicators in de grafiek)