===== NL7559KW7/Abs.Vocht-informatie [Testend => alleen ter info & evaluatie!!!] ===== Datum = 19-03-2025 Tijd = 21:05:01 Locatie => Rel.Vocht & Temperatuur => Abs.Vocht AV, Dampdruk (=P) & Dauwpunt (=Td) Buiten-sensors, tuin +2,5m (1*) => 50.0 % 8.4 °C => AV= 4.2 g/m^3 @ P= 5.5 hPa & Td= -1.3 °C +1,5m (3*) => 71.3 % 4.9 °C => AV= 4.7 g/m^3 @ P= 6.2 hPa & Td= 0.2 °C +0,1m (1*) => 70.0 % 7.1 °C => AV= 5.5 g/m^3 @ P= 7.1 hPa & Td= 2.1 °C Referentie-sensors, binnen/ begane grond +0,05m(2*) => 55.0 % 16.5 °C => AV= 7.7 g/m^3 @ P= 10.3 hPa & Td= 7.8 °C Kruipruimte-sensors -0,5m (1*) => 92.0 % 10.5 °C => AV= 8.9 g/m^3 @ P= 11.7 hPa & Td= 9.5 °C -0,8m (2*) => 95.5 % 12.8 °C => AV= 10.8 g/m^3 @ P= 14.1 hPa & Td= 12.4 °C -1,1m (1*) => 54.0 % 11.2 °C => AV= 5.5 g/m^3 @ P= 7.2 hPa & Td= 0 °C => R.V. Piekwaarde : RV_Buiten = 79.0 % => A.V. Gemiddeld : AV_Buiten = 5.0 g/m^3 & AV_Kruipruimte = 10.0 g/m^3 => Delta_AV = -5.0 g/m^3 => Tdauw Gemiddeld : Td_Buiten = 0.0 °C & Td_Kruipruimte = 11.0 °C => Delta_Tdauw = -11.0 °C [ Gewenst voor ventilatie: RV_Buiten < 75% @ T > 12°C, met Delta_AV << 0 en Delta_Tdauw << 0 ] => Ventilatie-advies = Ventileren? Foute HP3001-sensoren krijgen vervangingswaarden (als indicators in de grafiek)